Skip to main content

Chip & Pin Error Guide

Find out what to check if you see a Chip & PIN error when you take a card payment.

Written by Jasmine

Chip & PIN payments rely on several components working together. Some run on your PC, one runs on your central server, and one runs in the Access PaySuite data centre. All of these components need a network connection between them. If a payment fails, the sections below help you find which component is causing the problem.

Components on your PC

Chip & PIN processing is carried out by the following services. They need to be running on your PC alongside Counter Receipting or Paye.Net.

  • Smart Client.

  • SmartNS.

These applications start automatically when you start Counter Receipting. If you use Paye.Net, which is a browser-based application, you must start Smart Client manually. To do this, click the Access PaySuite Chip & PIN icon on your desktop.

Smart Client appears as a Credit Card icon in the Windows System Tray.

If any of the services don't appear to be running, run the Access PaySuite Chip & PIN start-up utility again. This won't start the programs twice. It only starts the ones that aren't running.

Smart Client errors

If Smart Client isn't running or is busy, you may see this error in Paye.Net: ‘Payment Authorisation cannot proceed. Chip and PIN - Response Code: 93 - Message: Failure connecting to Chip Client’

Access Care Rostering shows the same message box.

Check that Smart Client is running. Also check that no Smart Client prompt is hidden behind another window.

SmartNS errors

If SmartNS isn't running, you may see this error: ‘Cannot connect to the device.’


Switch User feature

Chip & PIN processing doesn't support the Switch User feature in Windows. Smart Client starts for each user logged on to a PC, so using Switch User runs multiple copies of Smart Client.

The server communicates with Smart Client on a fixed network port number. This means that both copies of Smart Client receive the same communications and try to process them at the same time, which causes errors.

⚠️Warning: Only one user can be logged in and running Smart Client at any one time.

The first user must log out, and the second user must log in to the PC, rather than using the Switch User option.


Smart Server on your central server

Chip & PIN also needs a service called Smart Server to be running on a central server. This is typically the same server that runs Income Management.

If Smart Server isn't running, you can't authorise transactions. You may see one of the following messages. Either Smart Server isn't running, or a network problem is stopping your PC from communicating with it.

[Transaction declined. Please remove the card. Declined due to network failure.]

If you see one of these messages, contact your network administrator or IT department.


Secure Bureau Service (SBS)

The SBS runs in the Access PaySuite secure data centre. It's designed to be resilient and is usually available around the clock. Scheduled maintenance takes place outside normal working hours and is notified in advance.

The SBS connects over the internet, so an interruption to your internet connection affects the service. Access PaySuite has made its internet connection to the data centre resilient.

Smart Server must connect to the SBS. Without this connection, you can't authorise card payments.

Depending on how your system is configured, you may see the following message. If you do, you may be able to authorise the payment manually by telephoning the acquirer.

[There has been a network error authorising the transaction. Please contact the acquirer by phone and insert the Authorisation Code given by them into the box below.]

⚠️Important: Your system may not have the manual authorisation option. It poses a slightly higher security risk, because card data must be stored on your central server until the connection to the SBS is restored. This card data is encrypted with asymmetric encryption and can't be encrypted on-site. As such, this doesn't contravene the PA-DSS status of the application.

Did this answer your question?